Consultation Hotline: 400-101-3651

Oil-Immersed Amorphous Alloy Distribution Transformer


Amorphous alloy distribution transformer uses a new type of permeability magnetic material: amorphous alloy. The iron core is made up from amorphous alloy and in the structure of three phases and five columns. Amorphous alloy core is processed with annealing treatment. The iron yoke is staggeringly jointed. The iron core and winding coils both have rectangular cross sections.

These transformers are widely used in industrial engineering, agriculture and urban communities, especially in the power network of the countryside and developing areas.

Product introduction



Working Conditions:
No.
Conditions
Units
Parameter Values
1
Pollution Grade
 
IV
2
Ambient Temperature
Maximum Daily Temperature
40
Minimum Daily Temperature
-45
Maximum Daily Temperature Difference
K
25
Average Temperature of the Hottest Month
30
Maximum Annual Average Temperature
20
3
Humidity
Average Daily Relative Humidity
%
≤95
Average Monthly Relative Humidity
≤90
4
Altitude
m
1000
5
Solar Radiation Intensity
W/cm2
0.1
6
Maximum Icing Thickness
mm
10
7
Maximum average wind speed: keeping in good conditions for 10min at 10m from the ground level
m/s
35
8
Earthquake Resistance
Horizontal Ground Acceleration
m/s2
2
Safety Coefficient of 3 Since Resonance Cycles
 
≥1.67
9
Installation Site
 
Outdoor
Note 1: Working conditions in high altitude regions (above 1000m) must be adjusted in conformity with Q/GDW 13001-2014 (High Altitude External Insulation Configuration Technical Specification).


Product Parameters:
Table 1  30kVA~2500kVA, Three-Phase Duplex Windings, No-Load Voltage Regulation, Distribution Transformer (SH15 Series)
Rated Capacity (kVA)
Voltage Combination & Tapping Range
Connection Symbol
No-Load Loss (W)
On-Load Loss (W)
No-Load Current (%)
Short-Circuit Impedance (%)
Acoustic Power Level dB(A)
High Voltage (kV)
High Voltage Tapping Range (%)
Low Voltage (kV)
30
6
6.3
10
10.5
11
±2×2.5
±5
0.4
Dyn11
33
630/600
1.50
4.0
52
50
43
910/870
1.20
53
63
50
1 090/1 040
1.10
80
60
1 310/1 250
1.00
55
100
75
1 580/1 500
0.90
125
85
1 890/1 800
0.80
59
160
100
2 310/2 200
0.60
200
120
2 730/2 600
0.60
61
250
140
3 200/3 050
0.60
315
170
3 830/3 650
0.50
64
400
200
4 520/4 300
0.50
500
240
5 410/5 150
0.50
66
630
320
6 200
0.30
4.5
800
380
7 500
0.30
68
1 000
450
10 300
0.30
1 250
530
12 000
0.20
72
1 600
630
14 500
0.20
2 000
750
18 300
0.20
5
73
2 500
900
21 200
0.20
Note 1: Transformers of “Yyn0” can also be supplied upon demands if the iron core is in the structure of three phases and three columns.
Note 2: If the rated capacity is 500kV.A or below, the data of “On-Load Loss” on the left of slash (/) is suitable for Dyn11, on the right for Yyn0.
Note 3: Transformers with other loss values can also be supplied upon demands.
Note 4: Three-phase transformers with other high voltage tapping range can also be supplied upon demands.


Table 2  30kVA~2 500kVA, Three-Phase Duplex Windings, No-Load Voltage Regulation, Distribution Transformer (SH16 Series)
Rated Capacity (kVA)
Voltage Combination & Tapping Range
Connection Symbol
No-Load Loss (W)
On-Load Loss (W)
No-Load Current (%)
Short-Circuit Impedance (%)
Acoustic Power Level dB(A)
High Voltage (kV)
High Voltage Tapping Range (%)
Low Voltage (kV)
30
6
6.3
10
10.5
11
±2×2.5
±5
0.4
Dyn11
33
565/540
1.50
4.0
52
50
43
820/785
1.20
53
63
50
980/935
1.10
80
60
1 180/1 120
1.00
55
100
75
1 420/1 350
0.90
125
85
1 700/1 620
0.80
59
160
100
2 080/1 980
0.60
200
120
2 450/2 340
0.60
61
250
140
2 880/2 740
0.60
315
170
3 440/3 280
0.50
64
400
200
4 070/3 870
0.50
500
240
4 870/4 630
0.50
66
630
320
5 580
0.30
4.5
800
380
6 750
0.30
68
1 000
450
9 270
0.30
1 250
530
10 800
0.20
72
1 600
630
13 000
0.20
2 000
750
16 400
0.20
5
73
2 500
900
19 000
0.20
Note 1: Transformers of “Yyn0” can also be supplied upon demands if the iron core is in the structure of three phases and three columns.
Note 2: If the rated capacity is 500kV.A or below, the data of “On-Load Loss” on the left of slash (/) is suitable for Dyn11, on the right for Yyn0.
Note 3: Transformers with other loss values can also be supplied upon demands.
Note 4: Three-phase transformers with other high voltage tapping range can also be supplied upon demands.

Address: No.1, West Xuefu Road, Longling Industrial Park, Gaoxin District, Yiyang City, Hunan Province, 413000, China

Contact No.: 0737-2222100

QQ: 3013508896

E-mail: huaxiangbyq@163.com

©2018 All Rights Reserved by Huaxiang Xiangneng Technology Co., Ltd.     京ICP证000000号